E2E2-X14MD1 5M

E2E2-X14MD1 5M

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    Cylinder,Threaded-M18

  • 描述:

    SENSOR PROX INDUCTIVE 14MM CYL

  • 数据手册
  • 价格&库存
E2E2-X14MD1 5M 数据手册
Long-barrel Inductive Proximity Sensor E2E2 CSM_E2E2_DS_E_4_3 Proximity Sensor with a Long Screw Length • Increased tightening strength. Cable protectors provided as a standard feature. • Increased indicator visibility. A milled section for wrench grip on all models. Be sure to read Safety Precautions on page 9. Ordering Information Sensors DC 2-Wire Models Appearance Shielded Unshielded Sensing distance M12 M18 M30 M12 M18 M30 3 mm 7 mm 10 mm 8 mm 14 mm 20 mm Model Operation mode NO E2E2-X3D1 2M * E2E2-X7D1 2M * E2E2-X10D1 2M * E2E2-X8MD1 2M * E2E2-X14MD1 2M * E2E2-X20MD1 2M * NC E2E2-X3D2 2M E2E2-X7D2 2M E2E2-X10D2 2M E2E2-X8MD2 2M E2E2-X14MD2 2M E2E2-X20MD2 2M * Models with different frequencies are also available. The model numbers are E2E2-X@D15 (example: E2E2-X3D15). DC 3-Wire Models Appearance Shielded Unshielded Sensing distance M12 M18 M30 M12 M18 M30 2 mm 5 mm 10 mm 5 mm 10 mm 18 mm Model Operation mode NO E2E2-X2C1 2M E2E2-X5C1 2M E2E2-X10C1 2M E2E2-X5MC1 2M E2E2-X10MC1 2M E2E2-X18MC1 2M NC E2E2-X2C2 2M E2E2-X5C2 2M E2E2-X10C2 2M E2E2-X5MC2 2M E2E2-X10MC2 2M E2E2-X18MC2 2M AC 2-Wire Models Appearance Shielded Unshielded Sensing distance M12 M18 M30 M12 M18 M30 2 mm 5 mm 10 mm 5 mm 10 mm 18 mm Model Operation mode NO E2E2-X2Y1 2M E2E2-X5Y1 2M E2E2-X10Y1 2M E2E2-X5MY1 2M E2E2-X10MY1 2M E2E2-X18MY1 2M NC E2E2-X2Y2 2M E2E2-X5Y2 2M E2E2-X10Y2 2M E2E2-X5MY2 2M E2E2-X10MY2 2M E2E2-X18MY2 2M 1 E2E2 Accessories (Order Separately) Mounting Brackets Protective Covers Sputter Protective Covers Ratings and Specifications E2E2-X@D@ DC 2-Wire Models Size Shielding Item Model Sensing distance M12 Shielded E2E2-X3D@ M18 Unshielded E2E2-X8MD@ Shielded E2E2-X7D@ M30 Unshielded E2E2-X14MD@ Shielded E2E2-X10D@ Unshielded E2E2-X20MD@ 3 mm±10% 8 mm±10% 7 mm±10% 14 mm±10% 10 mm±10% 20 mm±10% Set distance *1 0 to 2.4 mm 0 to 6.4 mm 0 to 5.6 mm 0 to 11.2 mm 0 to 8 mm 0 to 16 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, Iron, Iron, Iron, Iron, Iron, 12 × 12 × 1 mm 30 × 30 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm Response frequency *2 1 kHz Power supply voltage (operating voltage range) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Leakage current 0.8 mA max. Control output Switching capacity 800 Hz 500 Hz 400 Hz 100 Hz 3 to 100 mA Residual voltage 3 V max. (Load current: 100 mA, Cable length: 2 m) Indicators D1 Models: Operation indicator (red) and setting indicator (green) D2 Models: Operation indicator (red) Operation mode (with sensing object approaching) D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. D2 Models: NC Protection circuits Surge absorber, Load short-circuit protection Ambient temperature Operating/Storage: −25 to 70°C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1000 VAC, 50/60 Hz for 1 minute between current-carrying parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 65 g Case Materials Approx. 150 g Approx. 210 g Brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Accessories Instruction sheet *1. Use the E2E2 within the range in which the setting indicator (green LED) is ON (except D2 Models). *2. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. 2 E2E2 E2E2-X@C@ DC 3-Wire Models Size Shielding Item Model M12 M18 M30 Shielded Unshielded Shielded Unshielded Shielded Unshielded E2E2-X2C@ E2E2-X5MC@ E2E2-X5C@ E2E2-X10MC@ E2E2-X10C@ E2E2-X18MC@ Sensing distance 2 mm±10% 5 mm±10% 5 mm±10% 10 mm±10% 10 mm±10% 18 mm±10% Set distance 0 to 1.6 mm 0 to 4 mm 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, Iron, Iron, Iron, Iron, Iron, 12 × 12 × 1 mm 15 × 15 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm Response frequency *1 1.5 kHz Power supply voltage (operating voltage range) *2 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. Leakage current 13 mA max. Control output Load current 400 Hz 600 Hz 200 Hz 400 Hz 100 Hz NPN open-collector output, 200 mA max. (30 VDC max.) Residual voltage 2 V max. (Load current: 200 mA, Cable length: 2 m) Indicators Operation indicator (red) Operation mode (with sensing object approaching) C1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. C2 Models: NC Protection circuits Reverse polarity protection, Surge absorber, Load short-circuit protection Ambient temperature Operating/Storage: −40 to 85°C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between current carry parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models Weight (packed state) Approx. 75 g Case Materials Approx. 160 g Approx. 220 g Brass Sensing surface PBT Clamping nuts Nickel-plated brass Toothed washer Zinc-plated iron Accessories Instruction sheet *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. A full-wave rectification power supply of 24 VDC ±20% (average value) can be used. 3 E2E2 E2E2-X@Y@ AC 2-Wire Models Size Shielding Item Model M12 M18 M30 Shielded Unshielded Shielded Unshielded Shielded Unshielded E2E2-X2Y@ E2E2-X5MY@ E2E2-X5Y@ E2E2-X10MY@ E2E2-X10Y@ E2E2-X18MY@ Sensing distance 2 mm±10% 5 mm±10% 5 mm±10% 10 mm±10% 10 mm±10% 18 mm±10% Set distance 0 to 1.6 mm 0 to 4 mm 0 to 4 mm 0 to 8 mm 0 to 8 mm 0 to 14 mm Differential travel 10% max. of sensing distance Sensing object Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.) Standard sensing object Iron, Iron, Iron, Iron, Iron, Iron, 12 × 12 × 1 mm 15 × 15 × 1 mm 18 × 18 × 1 mm 30 × 30 × 1 mm 30 × 30 × 1 mm 54 × 54 × 1 mm Response frequency 25 Hz Power supply voltage (operating voltage range) *1 24 to 240 VAC (20 to 264 VAC), 50/60 Hz Leakage current 1.7 mA max. Control output Load current *2 5 to 200 mA 5 to 300 mA Residual voltage Refer to Engineering Data on page 5. Indicators Operation indicator (red) Operation mode (with sensing object approaching) Y1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 8 for details. Y2 Models: NC Ambient temperature *1, 2 Operating/Storage: −40 to 85°C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95% (with no condensation) Temperature influence ±15% max. of sensing distance at 23°C in the temperature range of −40 to 85°C, ±10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C Voltage influence ±1% max. of sensing distance at rated voltage in the rated voltage ±15% range Insulation resistance 50 MΩ min. (at 500 VDC) between current-carrying parts and case Dielectric strength 4,000 VAC, 50/60 Hz for 1 minute between current carry parts and case Vibration resistance (destruction) 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions Shock resistance (destruction) 1,000 m/s2 10 times each in X, Y, and Z directions Degree of protection IEC IP67, in-house standard for oil resistance Connection method Pre-wired Models (Standard cable length: 2 m) and Connector Models Weight (packed state) Approx. 65 g Case Materials Approx. 150 g Approx. 210 g Brass Sensing surface PBT Clamping nuts Toothed washer Accessories Nickel-plated brass Zinc-plated iron Instruction sheet *1. When supplying 24 VAC to any of the above models, make sure that the operating ambient temperature range is at least −25°C to 85°C. *2. When using an M18 or M30 Connector Model at an ambient temperature between 70 and 85°C, make sure that the Sensor has a control output (load current) of 5 to 200 mA max. 4 E2E2 Engineering Data (Reference Value) E2E2-X@C@/-X@Y@ 12 Distance X (mm) Distance X (mm) Sensing Area Shielded Models E2E2-X@D@ E2E2-X10 10 8 12 E2E2-X10 10 Y 8 X E2E2-X7 6 6 E2E2-X5 4 4 Y E2E2 -X2 E2E2-X3 X 2 0 −20 2 −15 −10 −5 0 5 10 15 0 −15 20 −10 −5 0 5 Distance Y (mm) 25 20 30 Y X 25 20 E2E2 -X20M 15 E2E2-X18M 15 E2E2 -X14M 10 X E2E2-X10M 10 E2E2 -X8M Y E2E2-X5M 5 0 −30 5 −20 −10 0 10 20 0 −30 30 −20 −10 0 10 Distance Y (mm) Leakage Current E2E2-X@D@ 20 30 Distance Y (mm) Residual Output Voltage E2E2-X@D@ 1.0 0.8 0.6 Residual output voltage (V) E2E2-X@Y@ Leakage current (mA) Leakage current (mA) 15 E2E2-X@MC@/-X@MY@ 30 Distance X (mm) Distance X (mm) Unshielded Models E2E2-X@MD@ 10 Distance Y (mm) 1.4 1.2 1.0 0.8 0.4 0.6 6 5 4 3 Protective resistance 0.4 mA 0.2 0.2 0 5 10 15 20 25 30 Power supply voltage (V) 0 2 AC power V Proximity Sensor (OFF) 50 100 150 200 250 300 Power supply voltage (V) 1 3 5 10 30 50 100 Load current (mA) 5 E2E2 30 E2E2-X@Y@ 25 20 at 100 VAC 120 Residual output voltage 100 ON 80 Residual output voltage 60 15 VL 30 50 OFF 300 500 100 0 40 Residual load voltage 1 3 5 10 30 50 100 t = 1 mm 3 Iron 0 1 3 5 10 30 50 8 @d X 7 OFF 300 500 100 Load current (mA) E2E2-X10D@ t = 1 mm Distance X (mm) X 3.5 Distance (mm) Distance X (mm) Influence of Sensing Object Size and Material E2E2-X3D@ E2E2-X7D@ @d Residual load voltage OFF 300 500 Load current (mA) Load current (mA) 4 200 VAC 80 20 Residual load voltage 10 VL A 24 VAC 5 5 160 120 40 A 3 ON 100 VAC A 1 Residual output voltage 200 V VL V 0 at 200 VAC 240 V ON 10 E2E2-X@Y@ Load voltage VL (V) at 24 VAC Load voltage VL (V) Load voltage VL (V) E2E2-X@Y@ Iron 6 12 @d X t = 1 mm Iron 10 8 2.5 5 Stainless steel (SUS304) 2 Stainless steel (SUS304) 4 6 Stainless steel (SUS304) 4 Brass Aluminum Copper Brass 1.5 Brass 3 Aluminum Copper 1 Aluminum Copper 2 2 0.5 5 10 15 20 25 30 35 40 0 10 20 Side length of sensing object d (mm) 12 @d X 40 t = 1 mm 10 8 0 50 E2E2-X14MD@ Distance X (mm) Distance X (mm) E2E2-X8MD@ 30 10 20 25 @d X 30 40 50 70 E2E2-X20MD@ t = 1 mm 20 25 @d X t = 1 mm 20 Iron Iron 15 15 Iron 6 Stainless steel (SUS304) 10 Brass Aluminum Copper 2 10 20 30 40 50 60 Brass Aluminum Copper 5 70 Side length of sensing object d (mm) 0 Stainless steel (SUS304) Stainless steel (SUS304) 4 0 60 Side length of sensing object d (mm) Side length of sensing object d (mm) Distance X (mm) 0 1 10 20 30 40 50 60 10 Brass Aluminum Copper 5 70 Side length of sensing object d (mm) 0 10 20 30 40 50 60 70 80 90 100 Side length of sensing object d (mm) 6 E2E2 @d X E2E2-X5C@/-X5Y@ t = 1 mm Iron 2 7 @d t = 1 mm X 6 E2E2-X10C@/-X10Y@ Distance X (mm) 2.5 Distance X (mm) Distance X (mm) E2E2-X2C@/-X2Y@ Iron 5 12 @d X t = 1 mm Iron 10 8 Stainless steel (SUS304) Stainless steel (SUS304) 1.5 4 Stainless steel (SUS304) 6 3 1 Brass Brass Brass Aluminum Aluminum Aluminum 0.5 4 2 2 1 5 10 15 20 0 25 10 Side length of sensing object d (mm) 7 6 @d X 30 40 50 E2E2-X10MC@/-X10MY@ Distance X (mm) Distance X (mm) E2E2-X5MC@/-X5MY@ 20 t = 1 mm Iron 5 0 10 20 Side length of sensing object d (mm) 12 @d X 30 40 50 60 Side length of sensing object d (mm) E2E2-X18MC@/-X18MY@ t = 1 mm Iron 10 Distance X (mm) 0 25 @d X t = 1 mm 20 Iron 8 15 4 Stainless steel (SUS304) Stainless steel (SUS304) Stainless steel (SUS304) 6 3 10 2 Aluminum Aluminum 2 1 0 10 20 30 40 50 Side length of sensing object d (mm) 0 Brass Brass 4 Brass 10 20 30 40 50 60 Side length of sensing object d (mm) Aluminum 5 0 20 40 60 80 100 Side length of sensing object d (mm) 7 E2E2 I/O Circuit Diagrams DC 2-Wire Models Operation mode Model Timing Charts Non-sensing area Output circuit Unstable Set position sensing Stable sensing area area Proximity Sensor NO E2E2-X3D1 E2E2-X7D1 E2E2-X10D1 E2E2-X8MD1 E2E2-X14MD1 E2E2-X20MD1 Sensing object (%) 100 80 Rated sensing distance 0 ON Setting indicator OFF (green) ON Operation OFF indicator (red) ON Control output OFF Non-sensing area Brown Load +V Proximity Sensor main circuit Blue Stable sensing area 0V Proximity Sensor NC E2E2-X3D2 E2E2-X7D2 E2E2-X10D2 E2E2-X8MD2 E2E2-X14MD2 E2E2-X20MD2 Sensing object (%) Note: The load can be connected to either the +V or 0 V side. 100 0 Rated sensing distance ON Operation OFF indicator (red) ON Control output OFF DC 3-Wire Models Operation mode NO NC Model E2E2-X2C1 E2E2-X5C1 E2E2-X10C1 E2E2-X5MC1 E2E2-X10MC1 E2E2-X18MC1 E2E2-X2C2 E2E2-X5C2 E2E2-X10C2 E2E2-X5MC2 E2E2-X10MC2 E2E2-X18MC2 Timing Charts Sensing object Present Not present Operation indicator (red) OFF Present Not present Operation indicator (red) Control output Brown ON +V 100 Ω OFF Load ON Control output Sensing object Output circuit Proximity Sensor main circuit Black Blue 0V ON OFF ON OFF 8 E2E2 AC 2-Wire Models Operation mode NO NC Model Timing Charts E2E2-X2Y1 E2E2-X5Y1 E2E2-X10Y1 E2E2-X5MY1 E2E2-X10MY1 E2E2-X18MY1 E2E2-X2Y2 E2E2-X5Y2 E2E2-X10Y2 E2E2-X5MY2 E2E2-X10MY2 E2E2-X18MY2 Sensing object Present Not present ON Operation indicator (red) Brown OFF Load ON Control output Sensing object Output circuit Proximity Sensor main circuit OFF Present Not present Operation indicator (red) Control output Blue ON OFF ON OFF Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. ● Design Influence of Surrounding Metal When mounting the Sensor within a metal panel, ensure that the clearances given in the following table are maintained. l n m d dia. D m l (Unit: mm) Model Item Shielded DC 2-Wire Models E2E2-X@D@ Unshielded Shielded DC 3-Wire Models E2E2-X@C@ AC 2-Wire Models E2E2-X@Y@ Unshielded l d D m n l d D m n l d D m n l d D m n M12 0 12 0 8 18 15 40 15 20 40 0 12 0 8 18 15 40 15 20 36 M18 0 18 0 20 27 22 70 22 40 70 0 18 0 20 27 22 55 22 40 54 M30 0 30 0 40 45 30 90 30 70 90 0 30 0 40 45 30 90 30 70 90 9 E2E2 Mutual Interference When installing Sensors face-to-face or side-by-side, ensure that the minimum distances given in the following table are maintained. B Size A Mutual Interference (Unit: mm) Model Item M12 30 (20) M18 50 (30) M30 100 (50) B 20 (12) 35 (18) 70 (35) A 120 (60) 200 (100) 300 (100) B 100 (50) 110 (60) 200 (100) A B A B 30 20 120 100 50 35 200 110 100 70 300 200 A Shielded DC 2-Wire Models E2E2-X@D@ Unshielded DC 3-Wire Models E2E2-X@C@ AC 2-Wire Models E2E2-X@Y@ Relationship between Sizes and Models Shielded Unshielded Note: Values in parentheses apply to Sensors operating at different frequencies. Model E2E2-X3D@ Shielded E2E2-X2C@ E2E2-X2Y@ M12 E2E2-X8MD@ Unshielded E2E2-X5MC@ E2E2-X5MY@ E2E2-X7D@ Shielded E2E2-X5C@ E2E2-X5Y@ M18 E2E2-X14MD@ Unshielded E2E2-X10MC@ E2E2-X10MY@ E2E2-X10D@ Shielded E2E2-X10C@ E2E2-X10Y@ M30 E2E2-X20MD@ Unshielded E2E2-X18MC@ E2E2-X18MY@ tening Torque Do not tighten the nut with excessive force. A washer must be used with the nut. The following strengths assume washers are being used. ● Mounting T i g h Model Torque M12 M18 M30 30 N·m 70 N·m 180 N·m 10 E2E2 (Unit: mm) Dimensions Unless otherwise specified, the tolerance class IT16 is used for dimensions in this data sheet. Shielded Unshielded E2E2-X3D@/E2E2-X2C@/E2E2-X2Y@ 60 21 dia. 17 E2E2-X8MD@/E2E2-X5MC@/E2E2-X5MY@ 9 60 21 dia. 17 55 4 10 9 55 7 10 4 9 dia. *1 *1 Indicators *2 M12 × 1 Two clamping nuts Toothed washer *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) *1. 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.3 mm2, Insulator diameter: 1.3 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) E2E2-X7D@/E2E2-X5C@/E2E2-X5Y@ E2E2-X14MD@/E2E2-X10MC@/E2E2-X10MY@ 65 29 dia. 24 Indicators *2 M12 × 1 Two clamping nuts Toothed washer 65 12 29 dia. 24 60 4 10 12 60 10 4 10 14.8 dia. *1 *1 Indicators *2 M18 × 1 Two clamping nuts Toothed washer E2E2-X10D@/E2E2-X10C@/E2E2-X10Y@ 42 dia. 36 5 Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) 70 65 Indicators *2 M18 × 1 E2E2-X20MD@/E2E2-X18MC@/E2E2-X18MY@ 70 12 42 dia. 36 10 12 65 13 5 10 26.8 dia. *1 *1 Indicators *2 M30 × 1.5 Indicators *2 M30 × 1.5 Two clamping nuts Toothed washer Two clamping nuts Toothed washer *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) *1. 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2, Insulator diameter: 1.9 mm), Standard length: 2 m The cable can be extended to up to 200 m (Separate metal conduit.) *2. D Models: Operation indicator (red) and setting indicator (green), C/Y Models: Operation indicator (red) Mounting Hole Dimensions Dimension F (mm) M12 M18 +0.5 12.5 0 +0.5 18.5 0 dia. M30 dia. 30.5 +0.5 0 dia. F Note 1. Two clamping nuts and one toothed washer are provided with each Sensors. 2. The model number is laser-marked on the cable section and milled section. In the interest of product improvement, specifications are subject to change without notice. 11 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.
E2E2-X14MD1 5M 价格&库存

很抱歉,暂时无法提供与“E2E2-X14MD1 5M”相匹配的价格&库存,您可以联系我们找货

免费人工找货